Walkway pads are protective mats fastened to a flat roof so the people who service your rooftop equipment walk on them instead of on the membrane. Roofing manufacturers call for them at every place people get onto the roof, such as hatches, doors and ladders, and around equipment that gets regular service. If your building has rooftop units and no defined path to them, foot traffic tends to land on the same spots of membrane visit after visit.
Why does foot traffic matter so much on a flat roof?
On a low-slope roof, the membrane is the waterproofing. Every service visit puts boots, ladders, tool bags and loose parts on that same layer. GAF describes its Crossgrip walkway product as protection for TPO roofs from heavy foot traffic and from dropped tools and maintenance equipment. Carlisle’s walkway data sheet says its pads are designed to protect the membrane in areas exposed to repetitive foot traffic.
Picture a technician coming up through the hatch, crossing to the same air handler, kneeling at the service side and now and then dropping a screw. Over time, that one route takes more wear than the rest of the roof. Our commercial roof repair page lists punctures from foot traffic, tools or debris among the common leak sources we look for.
Where do walkway pads belong?
The manufacturers are fairly consistent on this. Carlisle’s EPDM walkway pad data sheet says walkways must be installed at all traffic concentration points, such as roof hatches, access doors and rooftop ladders, regardless of how often they are used. It adds that walkways are also needed where rooftop equipment gets regular maintenance, which it defines as once a month or more. IKO’s TPO specification calls for pads at all roof access points and around rooftop equipment that may need maintenance. GAF’s heat-welded walkway pad detail says they are required at all roof access points.
In practice, a good layout covers:
- The landing at each hatch, door and roof ladder
- A path from those entry points to each rooftop unit, exhaust fan or other serviced equipment
- The service side of each unit, where technicians kneel and set down tools

How are walkway pads installed without causing new leaks?
A careless install can do harm. The manufacturer instructions share a few rules:
- Keep pads off the seams. GAF’s detail says not to cross seams and to keep pads 6 inches off each seam. Carlisle’s walkway roll sheet calls for a gap of at least 4 inches over field splices so the seams can still be reached later. IKO’s specification says to avoid placing pads over TPO seams.
- Leave gaps for water. Carlisle cuts walkway rolls into pieces no longer than 10 feet with at least a 1-inch gap between them for drainage. IKO uses the same 10-foot and 1-inch limits and says each section should be placed so it does not cause ponding water. GAF’s walkway roll sheet calls for rolls spaced at least 6 inches apart.
- Use the right attachment for the membrane. On TPO and PVC, many pads are heat-welded to the membrane, though GAF also sells a loose-laid walkway roll. IKO’s spec has the installer leave one or two 1-inch gaps in the weld on the downslope side so moisture can escape. Carlisle’s EPDM pads stick down with a primer over a cleaned surface. For ballasted systems, GAF’s details use paver walkways instead.
- Stay away from the roof edge. Carlisle’s walkway roll sheet says, for safety reasons, the rolls should not be installed within 10 feet of the roof perimeter, and that they are not a perimeter warning line.
Pads have to match the roof system, so the walkway material should come from the membrane’s manufacturer or be approved by it. Our TPO roofing page explains how that system is built.
Do walkway pads make the roof safe for technicians?
They help with slips, but they don’t replace fall protection. For people who work on a low-slope roof for an employer, OSHA’s rule at 29 CFR 1910.28(b)(13) sets distance bands from the roof edge. Work closer than 6 feet from the edge needs a guardrail, safety net, travel restraint or personal fall arrest system. Between 6 and 15 feet, the same protection applies, though a designated area can be used for work that is both infrequent and temporary. At 15 feet or more, the employer can use protection or a designated area, can skip fall protection for infrequent and temporary work, and must enforce a rule that no one goes within 15 feet of the edge without fall protection.
Those duties belong to each service company for its own workers. A walkway that stays well back from the edge makes them easier to follow.
What do Austin building codes say about rooftop equipment access?
The City of Austin adopted the 2024 International Building Code and the 2024 Uniform Mechanical Code with local amendments, effective July 10, 2025. The City lists the current editions on its Building Technical Codes page. The mechanical code has its own rules for reaching rooftop equipment, including an inside means of roof access on taller buildings and clearance or guards between the access opening and the roof edge.
Walkway pads don’t replace any of that. If you are adding or moving rooftop units, the mechanical side handles access. The roofing side makes sure new curbs and pads are tied into the membrane correctly.
What can a building owner do without a contractor?
A good part of this is housekeeping, not roofing work:
- Keep a sign-in log for roof access, so you know who was up there and when.
- Ask every vendor to stay on the walkway and carry out screws, filters, panels and packaging.
- Take a few photos of the walkway and the areas around units after big service visits, so new damage is easier to spot.
- Look at the roof after HVAC replacements, which bring extra people, equipment, curbs and lines onto it.
When pads are torn, missing or placed across seams, or when the paths no longer match where the equipment sits, that is a job for a roofer who works on your membrane type. Walkway checks fit well into a commercial roof maintenance visit, and our commercial roofing page covers the systems we work on.
Ridgepoint Solutions works on flat and low-slope roofs across Austin and surrounding Central Texas communities. If you’d like the traffic routes on your roof looked at and a written scope for walkway pads or repairs, Get a free estimate or email info@ridgepoint-solutions.com.
Frequently asked questions
Are walkway pads required on a commercial roof?
Roofing manufacturers call for them in their installation instructions. Carlisle says walkways must go at all traffic concentration points, such as hatches, doors and ladders, and where equipment is serviced once a month or more. GAF’s walkway detail says pads are required at all roof access points, and IKO’s specification calls for them at access points and around equipment that needs maintenance. Check the instructions for the system already on your roof.
Can walkway pads go over the seams of a TPO roof?
No. GAF’s detail says to keep walkway pads 6 inches off each seam, and IKO’s TPO specification says to avoid placing pads over seams. Carlisle leaves a gap of at least 4 inches over field splices so the seams stay reachable for inspection and repair. A pad welded across a seam hides a common leak point and makes a later repair there harder.
Do walkway pads trap water on the roof?
They can if they are laid edge to edge. Carlisle and IKO both call for sections no longer than 10 feet with at least a 1-inch gap between them, and IKO says pads should be placed so they don’t cause ponding. GAF’s walkway roll sheet calls for 6 inches between rolls. IKO also has installers leave small openings in the weld on the low side so moisture under a pad can drain out.